DC Loadbank PDL
NIAWELL · INDUSTRIAL EQUIPMENT
Load Bank · DC

DC Loadbank PDL

PDL

The PDL series DC loadbank is an advanced tool for testing, discharging, and evaluating the performance of various industrial batteries. This device, capable of operating in three operating modes CC (constant current), CP (constant power) and CR (constant…

Industrial design & manufacturing Technical consultation Customizable
Product overview

Description

The PDL series DC loadbank is an advanced tool for testing, discharging, and evaluating the performance of various industrial batteries. This device, capable of operating in three operating modes CC (constant current), CP (constant power) and CR (constant resistance) and with a wide voltage range from 10 to 500 volts, is ideal for testing nickel-cadmium (Ni-Cd), lead-acid and lithium batteries. The compact design and high power density make it easy to use in space-constrained environments. Precise current control with accuracy of less than 0.5 A ensures a stable and reliable discharge. The Central Supervision Unit (CSU) monitoring and control module enables remote monitoring and system management. Test results can be viewed, saved and edited on a personal computer via the Niawell CSU Logger software provided with the device. In addition, comprehensive data logging, real-time charts and generation of PDF reports enable precise and professional analysis of battery performance. The simple user interface, quick setup and stable operation make the PDL a smart choice for industrial testing centers.</br></br>
NIAWELL

Key features

  • Wide input voltage range (500 ~ 10)
  • High power in a small volume
  • Precise constant current control with accuracy less than 0.5 A
  • Separate monitor and control section from the device
  • Ability to test batteries under real load
  • Real-time reporting and plotting during the test
  • Ability to test various batteries (Nickel-Cadmium - Lead-Acid - Lithium)
  • Dynamic discharge technology - maximum current at all voltages
  • Support for parallel operation to increase power capacity
APPLICATIONS

Applications

  • Industrial battery and high voltage testing centers
  • Power plants
  • Telecommunications industries
  • Rail and metro systems
  • Oil and gas industry
  • Military and aerospace industries
  • Data centers
TECHNICAL DATA

Specifications

The specifications use the same table structure as the DocMaker catalogue, with shared values merged across applicable models.

Electrical specifications

Specifications PDL-500-40KPDL 500-80K
Input voltage range 10 ~ 500
Output power 40 KW80 KW
Maximum current 110 A200 A
Auxiliary input power AC 220V, 50HZ, 6A
Cooling method Vertical airflow by fan
Modes Current Mode - Power Mode - Resistance Mode
Minimum load step 0.5A (Current Mode), 100W (Power Mode), 0.1Ω (Resistance Mode)
Type of power switch Power IGBT & MOSFET
Protections Fan failure - Thermal cut-outs - Overload protection - Emergency stop button - Reverse Polarity

Physical specifications

Specifications PDL-500-40KPDL 500-80K
Weight 55 KG85 KG
Dimensions (W×L×H) cm 35×78×5046×95×75

Environmental conditions

Specifications PDL-500-40KPDL 500-80K
Temperature range (°C) 0-50 °C for indoor use
Storage and Transportation -40°C to +70°C (-40°F to +158°F)
Humidity 5% – 95% RH, non-condensing
Operating Altitude 3000 m (10000 ft)

General Features

Specifications PDL-500-40KPDL 500-80K
Testable Items Batteries & DC Power Supplies
Capabilities Graphing – Centralized control remotely via network cable
Test Storage Stores last 12 tests for review with PDF export

Items

Specifications PDL-500-40KPDL 500-80K
Accessories CSU - Power Cable with connectors - Auxiliary power supply - Network cable - Cable for log - Case for auxiliarys parts - Cover