Load Banks

3PH-100KW AC Load Bank — 100 kW

Product seriesAC 100 kW Load Bank Exact model3PH-100KW Rated power100 kW Installation & mobilityPortable

Niawell 3PH-100KW 100 kW three-phase AC load bank for generator and UPS testing, with 240/400 VAC input, forced-air cooling and industrial protection.

Industrial engineering Custom configurations Engineering support
OVERVIEW

About this model

Niawell 3PH-100KW is a 100 kW three-phase resistive AC load bank for generator, UPS and industrial power-system testing. It operates at 240/400 VAC, 50 Hz with 220 V single-phase auxiliary power, forced-air cooling and a 250 A three-phase main circuit breaker.
ENGINEERING SELECTION GUIDE

100 kW three-phase AC load bank for generator testing

The 3PH-100KW is a three-phase resistive AC load bank rated at 100 kW. Before a generator or UPS test, verify voltage, frequency, power factor, connection capacity and hot-air discharge against the equipment documentation and site conditions.

Typical test applications

  • Apply resistive loading to a generator at agreed test points
  • Check UPS and AC source response under a defined load
  • Record voltage, current, frequency and thermal behaviour during testing

Confirm before specifying

  • Generator nameplate power, voltage and frequency
  • Cables, overcurrent protection, earthing and loading limits
  • Cooling-air intake, hot-air outlet, test duration and abort criteria

Engineering questions

Can it be used for diesel-generator load testing?

It can be evaluated for resistive testing of a suitable AC generator. Confirm power, voltage, frequency and the approved test profile first.

Does this model provide reactive load?

The available model specification describes resistive loading. A separate appropriate setup is needed when reactive loading or a specified power factor is required.

What is needed before requesting a quotation?

Share the generator nameplate, kW/kVA, voltage, frequency, site location and intended loading profile.

Need model-specific engineering advice?

Prepare source ratings, voltage, power, test duration and site details.

TECHNICAL DATA

Exact technical specifications

The data below comes directly from this exact model record and is never substituted with another power rating.

Select a model. Scroll the desktop comparison table horizontally to see all models.

Compare series modelsChoose a model above; mobile shows only the selected model.
Specification 3PH-100KW 100 kW · Portable
Electrical Ratings
Model 3PH-100KW
Main Input Voltage 240/400 VAC, 3-phase, 50 Hz
Rated Power 100 kW
Auxiliary Power Supply 220 V, 1-phase, 50 Hz
Cooling System
Cooling Forced-air cooling
Load Steps
Steps 2, 3, 5, 10, 20, 20, 40 kW
Mechanical Specifications
Dimensions (W × D × H) 46 × 100 × 93 cm
Weight 80 kg
Monitoring Features
Electrical Parameters Total Power, Voltage, Current, Frequency
Safety and Protection
Input Protection Main circuit breaker (250 A, 3-phase)
Branch Protection Fuse protection for each load branch
Fan Protection Fault detection via airflow detector
AC 100 kW Load Bank

3PH-100KW

100 kW · Portable

Model
3PH-100KW
Main Input Voltage
240/400 VAC, 3-phase, 50 Hz
Rated Power
100 kW
Auxiliary Power Supply
220 V, 1-phase, 50 Hz
Cooling
Forced-air cooling
Steps
2, 3, 5, 10, 20, 20, 40 kW
Dimensions (W × D × H)
46 × 100 × 93 cm
Weight
80 kg
Electrical Parameters
Total Power, Voltage, Current, Frequency
Input Protection
Main circuit breaker (250 A, 3-phase)
Branch Protection
Fuse protection for each load branch
Fan Protection
Fault detection via airflow detector
DOCUMENTS

Original verified documentation

Only verified original documents matching this model or technical series are shown here.

Technical consultation