DC Load Bank PDL 500-40K — 40 kW
Niawell PDL 500-40K 40 kW programmable DC load bank for battery and DC power-supply testing.
Device models
When should you choose the PDL 500-40K programmable DC load bank?
The 40 kW PDL 500-40K is designed for controlled loading of DC power sources and battery discharge tests within the exact model's documented operating limits. Confirm voltage, current, cables and the approved test plan before selection.
Typical test applications
- Check battery performance under a controlled DC load
- Observe DC supply or rectifier response at specified load points
- Record voltage and current against an agreed test procedure
Confirm before specifying
- DC voltage range, load current and required power
- Discharge cut-off voltage and battery safety limits
- Cable sizing, polarity, ventilation and test duration
Engineering questions
Is a 40 kW power rating enough to select this unit?
No. Verify its documented voltage and current limits, the test mode and the installation constraints as well as the power rating.
What information is needed for a battery discharge test?
Supply battery voltage and permitted range, required discharge current or power, end-voltage, duration and site safety requirements.
Can it test a three-phase AC generator?
No. The PDL 500-40K is a DC load bank; AC generator testing requires an appropriately rated AC load bank.
Exact technical specifications
The data below comes directly from this exact model record and is never substituted with another power rating.
Select a model. Scroll the desktop comparison table horizontally to see all models.
| Specification | PDL 500-80K 80 kW · 500 V | PDL 500-40K 40 kW · 500 V |
|---|---|---|
| Technical Specifications | ||
| Model | PDL 500-80K | PDL 500-40K |
| Load TypeShared | Programmable DC Load Bank | |
| Rated Power | 80 kW | 40 kW |
| Input Voltage RangeShared | 10–500 VDC | |
| Operating ModesShared | Constant current, constant power and constant resistance | |
| Reverse Polarity ProtectionShared | Yes | |
| CoolingShared | Forced-air cooling | |
| Control SystemShared | CSU supervisory control unit | |
| Auxiliary SupplyShared | 220 VAC, 50 Hz | |
| Dimensions (W × L × H) | 46 × 95 × 75 cm | 35 × 78 × 50 cm |
| Weight | 85 kg | 55 kg |
| Power SwitchingShared | IGBT and MOSFET | |
| Operating TemperatureShared | 0–50 °C, indoor use | |
| ApplicationsShared | Battery discharge testing and DC power-supply testing | |
PDL 500-80K
80 kW · 500 V
- Model
- PDL 500-80K
- Load Type
- Programmable DC Load Bank
- Rated Power
- 80 kW
- Input Voltage Range
- 10–500 VDC
- Operating Modes
- Constant current, constant power and constant resistance
- Reverse Polarity Protection
- Yes
- Cooling
- Forced-air cooling
- Control System
- CSU supervisory control unit
- Auxiliary Supply
- 220 VAC, 50 Hz
- Dimensions (W × L × H)
- 46 × 95 × 75 cm
- Weight
- 85 kg
- Power Switching
- IGBT and MOSFET
- Operating Temperature
- 0–50 °C, indoor use
- Applications
- Battery discharge testing and DC power-supply testing
PDL 500-40K
40 kW · 500 V
- Model
- PDL 500-40K
- Load Type
- Programmable DC Load Bank
- Rated Power
- 40 kW
- Input Voltage Range
- 10–500 VDC
- Operating Modes
- Constant current, constant power and constant resistance
- Reverse Polarity Protection
- Yes
- Cooling
- Forced-air cooling
- Control System
- CSU supervisory control unit
- Auxiliary Supply
- 220 VAC, 50 Hz
- Dimensions (W × L × H)
- 35 × 78 × 50 cm
- Weight
- 55 kg
- Power Switching
- IGBT and MOSFET
- Operating Temperature
- 0–50 °C, indoor use
- Applications
- Battery discharge testing and DC power-supply testing